| Model | Description | ||||
| NiCaVis 701 IQ NI | Spectral UV sensor for the measurement of nitrate, nitrate, CODtot, CODdiss, TOC, BOD, DOC, SACtot, | ||||
| SACdiss and UVT254 in the inlet and in the aeration. | |||||
| NiCaVis 705 IQ NI | Spectral UV sensor for the measurement of nitrate, nitrate, CODtot, CODdiss, TOC, BOD, DOC, SACtot, | ||||
| SACdiss and UVT254 in the drain/outlet. | |||||
| Model | NiCaVis 701 IQ NI | NiCaVis 705 IQ NI | |||
| Measuring method | Spectral measurement in the UV range of 200-390 nm | Spectral measurement in the UV range of 200-390 nm | |||
| Application (optimized for municipal wastewater treatment plants) | Infeed stimulation | Drain/output | |||
| Measuring range | 0.0 to 150.0 mg/L NO3-N | 0.00 to 50.00 mg/L NO3-N | |||
| 0.00 to 75.00 mg/L NO2-N | 0.00 to 25.00 mg/L NO2-N | ||||
| 0 to 20000/12500 mg/L COD (tot/diss) | 0.0 to 800.0 mg/L COD (tot/diss) | ||||
| 0 to 20000 mg/L TOC | 0.0 to 500.0 mg/L TOC | ||||
| 0 to 12500 mg/L DOC | 0.0 to 500.0 mg/L DOC | ||||
| 0 to 8000 mg/L BOD | 0.0 to 500.0 mg/L BOD | ||||
| 0 to 5000 m-1 SAC254 (tot/diss) | 0.0 to 600.0 m-1 SAC254 (tot/diss) | ||||
| 0.0 to 100.0% UVT254 | 0.0 to 100.0% UVT254 | ||||
| Cleaning | Maintenance-free WTW ultrasonic cleaning | Maintenance-free WTW ultrasonic cleaning | |||
| Material | Housing: Titanium, PEEK | Housing: Titanium, PEEK | |||
| Measuring window: Saphire glass | Measuring window: Saphire glass | ||||
| IQ SENSOR NET system | 282/284 and 2020 | 282/284 and 2020 | |||